- New





It automatically starts the generator and switches the power supply from the mains to the backup source in the event of a power cut.
Compatible with generators and 230/400 V mains supply, supports power up to 21.0 kW and a maximum current of 64/32 A.
Features manual and automatic modes, an 8-core control cable, a Summer/Winter switch, status indicator lights and a wall-mounted housing measuring 220×150×370 mm.
The Könner & Söhnen KS ATS 4/32-12 automatic transfer switch is designed to automatically control a generator set and switch the power supply from the mains to the backup generator and back. This is a practical solution for homes, holiday homes, workshops, shops, offices or other premises where it is important to maintain power to critical loads during mains power failures.
The model supports operation with a 230 V / 400 V mains supply and generator. For the 230 V mode, the maximum current is 64 A and the power is 14.0 kW, whilst for the 400 V mode, it is 32 A and 21.0 kW. Thanks to these parameters, the KS ATS 4/32-12 is suitable for building a stable backup power system with automatic power supply control. :contentReference[oaicite:1]{index=1}
The ATS unit can operate in two modes — manual and automatic. In automatic mode, the device continuously monitors the presence of voltage in the mains supply. If there is no voltage for 5 seconds, the system sends a signal to start the generator engine. Once the generator has started, the ATS automatically moves the damper to the correct position and, after a delay, connects the load to the backup source. :contentReference[oaicite:2]{index=2}
This model is equipped with a Summer/Winter switch. In summer mode, the start-up time is 10 seconds; in winter mode, it is 25 seconds. The manual also states that after the main power supply fails, the unit starts the backup generator in approximately 4±2 seconds, and switches the load back within 3 seconds once mains voltage is restored. If the generator does not start on the first attempt, the system makes repeated attempts, and after several failed starts, the alarm sounds. :contentReference[oaicite:3]{index=3}
The front panel features a power switch, an ATS mode switch, a generator-to-mains voltage switch, a manual generator start/stop button, and indicator lights for mains, load, generator power and engine operation. This allows for convenient monitoring of the system status and quick control of the backup power supply in manual mode. :contentReference[oaicite:4]{index=4}
The KS ATS 4/32-12 connects to the generator via an 8-pin output and an 8-core control cable, which is included in the kit. The unit itself is housed in a wall-mountable enclosure, and power lines are connected via terminal blocks inside the device. In ‘Auto’ mode, the unit also charges the generator’s battery simultaneously. :contentReference[oaicite:5]{index=5}
The model is designed to operate at ambient temperatures ranging from -10°C to +55°C, storage temperatures from -10°C to +70°C, relative humidity up to 60%, and installation altitudes up to 300 m above sea level. The dimensions of the housing are 220×150×370 mm, and the gross weight is 6.1 kg. :contentReference[oaicite:6]{index=6}
Könner & Söhnen KS ATS 4/32-12 package contents: